Files
road-compiler/.trellis/tasks/08-31-parameter-panel-binding/research
que01andClaude Opus 5 4b70b0221d docs: record the crosswalk inset dead zone
Sweeping the declared [0, 8] range and measuring where the group actually lands:
0 to 3.2 tracks one-to-one, and 3.2 to 8 does not move at all. No diagnostic, no
feedback — roughly 60% of the advertised range is inert.

crossingJunctionInset() drives it. targetDistance bottoms out once inset reaches
the approach's cutback, and a 4m cap sits above that, so the real ceiling varies
per approach while the manifest publishes a flat 8 for all of them.

This is worse than the edge-offset case already on file. That one refuses and
says so; this one silently does nothing, which is indistinguishable from a broken
control — the exact failure the interval flag exists to prevent, occurring in the
upper half of a range rather than across a whole handle. A user whose first drag
lands in the dead zone concludes direct editing does not work.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-31 14:11:57 +08:00
..